Australian made power transducers - Class 0.2 

 

AC CURRENT – VOLTAGE – FREQUENCY.
AC WATT, VAR, POWER FACTOR, WATT/HR, VAR/HR, WATT WATT/HR
DC WATT, VAR.
DC CURRENT – VOLTAGE .
SPECIFICATIONS
 
The Translite designed range of quality transducers fully complies with International British and Australian standards IEC688 & 414, BS6253 & 5483 and AS1384 having an accuracy of class 0.2.

These transducers are used to convert AC voltage, current, frequency or instantaneous power signals into load independent DC signals, proportional to the measured value. 

The output signal enables several receiving instruments, such as analogue meters, digital indicators, recorders, controllers, etc. to be operated simultaneously, both at the measuring point and/or at a distant location. The signal can also be used to drive programmable logic controllers (PLC's) and data processing equipment. 

A feature of these transducers is that the entire range is housed in two models of the same molded case, simplifying panel design and installation. Triple Current and Voltage, Watt Hour, Watt/Watt Hour, Var Hour, Var/Var Hour transducers consist of a power transducer and integrator housed in the 100mm (4”) case to produce both analogue and pulse output; the other models are housed in the 50mm (2”) case.

Each unit has a label providing electrical specification and wiring details. Special ranges, combined units or customer specials can be made to order. Preferred ranges are normally available from stock. 

F E A T U R E S 

Australian designed and manufactured.

Customized Labeling 
Flexible design – vast range of input to output combinations
Isolated input to output (4kV), impulse (5kV)
Load independent
All solid state – long term stability
Shock and vibration proof – mount in any position 
Trim adjustment for zero and full load 
Output terminals can short or open circuit without causing damage.
Molded housing with quick release cover (IP40 rating).
Trim adjustment for zero and full load 
Output terminals can short or open circuit without causing damage.
Molded housing with quick release cover (IP40 rating).
Universal mounting, clips to 35mm (1.375”) din rail or panel mount with 2 screws 
Label provides electrical specifications and wiring details. 
Outputs can be unidirectional, bi-directional or offset.
Combined multiple units e.g. Amps/Volts, custom built 
Accuracy class 0.2 to AS1384 complies with BS6253 & 5483, IEC688 & 414, and with UL1244 
 